COMBI MAX MBXXX

GENERAL FEATURES

    • Maximum output of 400 Wattages in Monopolar Pure Cutting.
    • 7 inch wide angle LCD touchscreen for better view/usability.
    • User adjustable blend ratio from 10% – 90% in Monopolar.
    • Special EndoCut mode for Polypectomy & Papillotomy.
    • Simultaneous Coagulation features with independent settings.
    • Lo & Hi Spray modes for non-contact superficial coagulation.
    • Randomized Spray ON/OFF feature in Lo/Hi Spray Modes.

<liclass=”mb-5″>Special Soft Mode for delicate /soft tissues and Neurosurgery.

  • Auto-Stop mode in Monopolar Coagulation for optimum result.
  • Auto Start – Auto Stop in Bipolar for optimum coagulation effect.
  • User adjustable delay in Auto-Start mode from 0.1/9.9 seconds.
  • 199 User programmable memory locations to save profile and preferred setting.
  • Audio-Visual indications of Error Messages, Instrument Short, Hand/Footswitch Error, Time-Out Error etc on real-time basis.
  • Restores previous activated settings during Power Up/Restart.
  • PPCM (Patient Plate Contact Monitoring System) deactivates output if it senses improper connection or less contact between patient and return electrode to eliminate risk of Patient Burns.
  • Unit is compatible with Wired Footswitch/Wireless Footswitch.
  • Well suited for General/Gynaec/Underwater Applications etc.
  • Unit can be upgraded with Argon Plasma Coagulation System Vessel Sealing System and Bipolar Saline TUR.

 

Category:

RELIABILITY

  • Basic Construction n accordance with IEC i standards.
  • Multiple micro-controller supervision for RF power accuracy.
  • Real time tissue impedance monitoring for power control.
  • Graphical split/non-split patient representation of plate contact . quality
  • Warnings Errors stored with timestamp for and are reviewing.
  • Built-in-line filter protects from voltage surges/bad line conditions.
  • Power up Self-Test to ensure unit healthiness.
  • Audio and Visual indication for easy interpretation.
  • Real-time Handswitch/Footswitch Short detection.

SAFETY

  • Works with input voltage of 110 VAC and 220 VAC.
  • PPCM – Patient Plate Contact Quality Monitoring System.
  • High Frequency Leakage monitoring and controlling system.
  • Autolock facility to prevent accidental change of settings.
  • Port ON/OFF control to prevent accidental RF any activation.
  • No power delivery if Patient Plate contact is less or insufficient.
  • Equipotential port for ground connection. additional
  • Type CF – Generator output is Floating (Isolated).
  • Convection cooling system rolong unit’s life.

RF OUTPUT CHARACTERISTICS

MONOPOLAR CUT

  • Pure :- 400 W
  • Lap Cut :- 300 W
  • Blend :- 250 W
  • Endo Cut :- 10 Levels.

MONOPOLAR COAGULATION

  • Lo Spray :- 120 W
  • Hi Spray :- 70 W
  • Fulgurate :- 150 W
  • Lo Desiccate :- 120 W
  • Hi Desiccate :- 1 0 W 8
  • Soft :- 120 W
  • Auto Desiccate :- Auto
  • Auto Soft :- Auto
  • Randomized Spray Selections Available

BIPOLAR

  • Cut/Standard :- 120 W
  • Macro/Force :- 120 W
  • Micro/Precise :- 100 W
  • Auto Macro :- 120 W
  • Auto Micro :- 100 W

LIGATE

  • Ligate :-5 Levels
  • F-Ligate :-2 Levels

BIPOLAR (TUR) CUT

  • Low Cut :- 250 W
  • Hi Cut-1 :- 300 W
  • Hi Cut- :- 300 W 2
  • Hi Cut- :- 300 W 3
  • Effect 1 :- 300 W –
  • Effect :- 300 W

BIPOLAR (TUR) COAGULATION

  • Desiccate :- 250 W
  • Force :- 200 W

TECHNICAL DATA

TECHNICAL DATA

  • Input :- 220 / 230 VAC ± 20%,50Hz
  • Power Consumption :- 750VA Max.
  • Class :- I
  • Mdd. :- II B
  • Input Fuse :- 5 AT
  • Output Control :- 7” TFT Display with Touch Screen Push buttons all & Modes.
  • Nominal Freq. :- 360 / 550 KH

SAFETY STANDARDS

  • Unit type :- CF
  • PER :- 98
  • Electrical Potential :- Connecting Pin and Balancing Indicated by Symbol.
  • Basic Construction :- In accordance with
  • IEC 60601-1
  • IEC 60601-1-2 &
  • IEC 60601-2-2

DIMENSION

  • 420mm (L)
  • 380mm (W)
  • 170mm (H)

WEIGHT

  • 8 kg Max Weight .0 . imum .